Norsat ATOMControl Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
2 Monitoring Device Information
- 13 -
Note that the Power Fault is only detected on 100W BUCs and SSPAs.
Also note that the PLL Fault is only detected for BUCs, not SSPAs.
The SAT-7200 data set provides version information for the SAT-7200 Synthesizer
board used only with ATOM BUCs. SSPAs do not use the SAT-7200 and thus do not
provide any version information. The Hardware Version field shows the hardware
version for the SAT-7200 board, while the Firmware Version field shows the version of
the firmware running on the board.
The Temperature Readings data set shows the current temperature for each of the
Power Modules contained within the ATOM device in addition to the current temperature
of the device’s Driver Module. Measured temperatures range from -40°C to 125°C. Table
3 below shows the expected number of Power Modules for each type of ATOM device:
Device Type
Number of Power Modules
KU 25W BUC or SSPA
2 + 1 Driver Module
KU 40W BUC or SSPA
4 + 1 Driver Module
KU 50W BUC or SSPA
4 + 1 Driver Module
KU 100W BUC or SSPA
8 + 1 Driver Module
Table 3: Number of Expected Power Modules for Each ATOM Device Type
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 29 30

Commentaires sur ces manuels

Pas de commentaire